New

Thermistor-NTC-PTC

Thermistors are special solid temperature sensors that behave like temperature-sensitive electrical resistors.There are basically two broad types,NTC-Negative Temperature Coefficient,used mostly in temperature sensing and PTC-Positive Temperature Coefficient,used mostly in electric current control. They are mostly very small bits of special material that exhibit more than just temperature sensitivity.They are highly-sensitive and have very high reproducibility with resistance Vs. temperature properties. Thermistors,since they can be very small in size,are used inside many other devices as temperature sensing and correction devices as well as in specialty temperature sensing probes for commerce,science and industry. Thermistors typically work over a relatively small temperature range,compared to other temperature sensors and can be very accurate and precise within certain range.

.
New

Digital Temperature Gauge

Specifications:- Input :- RTD (Pt-100) & Thermocouple ‘K’ (Cr-al). Range :-As per your requirement. Indication :- 3½ Digit Seven Segment LCD ½”size. Accuracy of Indication :- ±0.5% of FSD ± 1digit Operating Temperature :- 0ºc to 50ºC Supply :- 9VDC (Battery) Probe Dia. :- 6.35mm, 8mm, and 9.5mm or as per your application.

.
New

100mm Panel Mounting Glycerin Filled Pressure Gauge

Our 100mm panel mounting micro glycerin filled pressure gauges are ideal for dampening the effect of vibration & pulsation. It also lubricate the movement and internal parts which extends the lite of gauge. It enhance the reliability and integrity of measuring system for long periods under extreme operating condition.

.
New

Bourdon Tube Pressure Gauge (Stainless Steel Series)

Specifications: Accuracy: ±1.0% of FS. Ambient Temperature: -25 Degree to 65 Degree Process Temperature: Max 300 Degree C. Operating Pressure Range: 75% of scale value. Over pressure Limit: < 100 bar : 125% of Max. Scale Value >100 to < 600 bar : 115% of Max. Scale Value > 600 to < 1600 bar : 110% of Max. Scale Value Protection: IP65

.
New

Diaphragm Pressure Gauge

Specifications Diaphragm Type: HP: -1 to 0 kg/cm & 0 to 10 kg/cm LP : -6000 mmWC to 0 & 0 to 6000 mmWC Accuracy: ±1.6% of F.S. Ambient Temperature: -20 Deg C to 65Deg C. Process Temperature: max 100 Degree C. OPerating Pressure Range: 75% of scale value. Over pressure limit: 125% of scale value. Gauge connection: 1/2″ BSP.

.
New

II Isolator

Specifications:- Input:- 4-20mA, 0-20mA, 0-1VDC, 0-5VDC, 0-10VDC etc Output:- 4-20mA, 0-20mA, 0-1VDC, 0-5VDC, 0-10VDC etc.(Single/Dual) Accuracy:- Better than +/- .5% FSD Isolation:- Optical & Galvanic Supply:- 230 VAC +/- 10% Ambient operating temperature range:- 0 to 50deg. C. Operating humidity limit:- 10 to 90%, Non-condensing.

.
New

IV Convertor

Specifications:- Input:- 4-20mA, 0-20mA, 0-1VDC, 0-5VDC, 0-10VDC etc Output:- 4-20mA, 0-20mA, 0-1VDC, 0-5VDC, 0-10VDC etc.(Single/Dual) Accuracy:- Better than +/- .5% FSD Isolation:- Optical & Galvanic Supply:- 230 VAC +/- 10% Ambient operating temperature range:- 0 to 50deg. C. Operating humidity limit:- 10 to 90%, Non-condensing.

.
New

Turtle Head Transmitter

We offer the range of Temperature transmitter having highly stable analog output (Current: 4-20mA) for Thermocouple & Pt-100 Input. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates that unit is operating in loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC. Operating Humidity Limit:- 10 to 90%, Non-condensing. Probe Diameter:- 4.7mm, 6.35mm,8mm etc. As per your application. Material of Encapsulation:- Epoxy.

.
New

Din Rail Transmitter

Specifications:- We offer the range of Temperature transmitter having highly stable analog output (Current: 4-20mA) for Thermocouple & Pt-100 Input. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates That Unit is Operating in Loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC. Operating Humidity Limit:- 10 to 90%, Non-condensing. Mounting:- Din Rail Mounting. Material of Encapsulation:- Epoxy.

.
New

Pressure Transmitter

Pressure transmitters translate low-level electrical outputs from pressure sensing devices to higher-level signals that are suitable for transmission and processing. They use many different sensing technologies and can measure the pressure of liquids and/or gases. Elastic elements when subjected to pressure get deformed. This deformation when measured gives an indication of the applied pressure. These elements may be in the form of Diaphragm, Bourdan Tube, Capsules, Bellows, and Helical Tube. Etc. These deformations can be measured by mechanical means. Features Head or Rail Mounting. Field mounting (Optional) Highly stable Analog design. Built in ‘cold junction compensation’ for thermocouple. Linearization & 3rd wire compensation for RTD. Wide supply voltage rang Compact & cost effective. Technical Specification Input : Pt-100 RTD, 2 OR 3wire. /Thermocouple Output : 2 wire 4 to 20mA corresponding to defined input temperature range. Operating Voltage : Nominally 24 VDC, can range from 12V to 36V. Maximum Load in Loop : 250 Ohm for 24VDC supply. Basic Accuracy:- +/- 0.5% of FSD. Ambient Operating Temperature Range:- 0 to50°C. Indication(s):- Red LED “ON” indicates that unit is operating in loop. Material of Encapsulation:- Epoxy.

.
New

Temperature Panel Mounting Transmitter

Specifications:- Input :- Pt-100RTD, 2 or 3 wire. / Thermocouple. Output :- 2 wire 4 to 20 mA corresponding to defined input temperature range. Operating Voltage :- Normally 24VDC,can range from 12V to 36V. Basic accuracy :- 0.5% of FSD Change of current o/p with Ambient Temperature :- <± 0.01% for span per ºC change Change of current o/p with supply voltage :- < ± 0.001% of span per volt, from 12V to 3V. Linearization Circuitry Error :- < 0.05% of span at any current. Ambient Operating Temperature Range :- 0ºC to 70ºC Indication :- Red LED “ON” indicates that units is operating in loop. Operating Humidity Limit :- 5 to 90%, Non-condensing. Material of Encapsulation :- Epoxy.

.
New

Humidity Transmitter

The Humidity sensor reacts very quickly on humidity leaps and measures accurately and free of any hysteresis. These characteristics suits especially good for a precise and quick control of the room climate. These are compact Transmitters for humidity, temperature and combined humidity / temperature with excellent price / performance ratio. Advantages: Calibration free Ready to use Precise humidity measurement Drift stable thanks to wide sensor area Available with optional temperature sensor Smallest dimensions Mechanical robust and easy to integrate Different output options on request Technical Data: Measurement Principle :- Capacitive humidity sensor Humidity measurement range :- 0 to 100%Rh Operating temperature :- -25 to +85°C Operating voltage :- 8 to 32VDC Current consumption : 4 to 20mA Output signal :- 4 to 20mA (0 to 100%Rh) Temperature sensor :- optional Pt100/Pt1000. Accuracy :- < 3% Rh Terminal connectors :- Soldering terminals for VCC, Analog out 4 to 20mA, Loop-through of optional temperature sensor.

.
New

Two Wire Loop Power Temperature Transmitter (Head Mounting)

Features: Head mounting/ Rail Mounting Highly stable Analog design. Built in ‘cold junction compensation’ for Thermocouple. Linearization & 3rd wire compensation for RTD. Wide supply voltage range Compact & cost effective. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates That Unit is Operating in Loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC Operating Humidity Limit:- 10 to 90%, Non-condensing. Material of Encapsulation:- Epoxy.

.
New

Electronic Hooter

Features Panel Mounting. Field mounting (Optional) Highly stable Analog design Multi tone Compact & cost effective Specification:- Sound:- 3 Sounds(Selectable with Toggle Switch) Sound Level:- 90-100 Db Accept:- On Front & Back. Indication:- Audio & Visual (LED) Indication. Supply:- 230VAC, ±10% Ambient Operating Temperature Range: 0 to 50 Deg.C Operating Humidity Limit :10 to 90%

.
New

Timer – Universal

Specifications:- Input: Proximity S/W or potential free contacts Display:4+4 Digit, 0.56″,Red LED Output: 1 C/O, 5A/10A resistive relay Supply: 230V/100VAC, ±10%, 50/60Hz Set Range: 0~9999 counts No. of Batches: 0~9999 batches Total Counts: 0~999999 counts Count Direction: UP Size: 72x72x113mm. (6 Digit Counter also available)

.
New

AM Station

Specification:- Features:- Panel Mounting Field mounting (Optional) Highly stable Analog design. Multi tone Compact & cost effective. Technical specifications:- Input:- 4-20mA, 0-20mA, 0-1VDC, 0-5VDC, 0-10VDC etc. Output:- 4-20mA, 0-20mA, 0-1VDC, 0-5VDC, 0-10VDC etc. (Single/Dual) Sound Level:- 80-90 Db Accept:- On front & Back Tone:- 3 Nos. Selection with switch supply:- 230VAC +/- 10% Ambient operating temperature range:- 0 to 50°C Operating humiditi limit:- 10 TO 90%, Non-Condensing.

.
New

Timer – Universal

1.Range:999.9sec,9999sec,99.59min,9999min,99.59hour 2.Accuracy: 0.01% or 100ms whichever is greater 3.Mode: ON/OFF delay, Cyclic ON/OFF First 4.Counting Method: Elapsed time (UP)/ Remaining time (Down). 5.Input Signals:Start, Hold, Reset 6.Start I/P metod: Instantaneous/ Pulse/ Gate start. 7.System: Front Key Configurable

.
New

Data Logger

Specifications:- Inputs :- RTD, R, S, K, J. (Selectable) Display Power Supply :- 230 VAC (50Hz) ± 10% Alarm Output :- Common Relay output for all channel. No. Of channel available :- 8, 16, 24, 32 channel etc. Online data recording :- For each channel is up to 500 / 1000 Recording interval :- 1 to 9999 MIN. Manual view scan time :- 1 to 200 SEC. Adjustable Mode :- Auto manual hold. Interface:- RS232 / 485 interface printer output. Memory capacity: 16 MB max expandable to 512 MB max (optional). Resolution: 0. 1 ºC up to 1600 ºC. Dimensions: 72 x 72 mm.

.
New

Magnetic Proximity Switches

2 Wire And 3 Wires DC Versions Available. Enclosure : Proximity Switches are available in Tubular shape made of BRASS, Plastic. Operating Temperature : Operating Temperature of Proximity Switches is O° to 55°c. and also upto 100 c°. can be manufactured on request.

.
New

Inductive Proximity Switches

DC Proximity Switches : These are available in 3 wires as shown in figure: Operating Voltage : 5V to 30 V DC Logic : PNP/NPN , NO/NC. Load :upto 400 mA AC Proximity Switches : These are available In 2 wires and 3 wires. These Switches are to be connected in series with the load. Operating Voltage :110 VAC / 240 VAC Logic :NO / NC / CO Load :upto 500 mA