New

Turtle Head Transmitter

We offer the range of Temperature transmitter having highly stable analog output (Current: 4-20mA) for Thermocouple & Pt-100 Input. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates that unit is operating in loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC. Operating Humidity Limit:- 10 to 90%, Non-condensing. Probe Diameter:- 4.7mm, 6.35mm,8mm etc. As per your application. Material of Encapsulation:- Epoxy.

.
New

Din Rail Transmitter

Specifications:- We offer the range of Temperature transmitter having highly stable analog output (Current: 4-20mA) for Thermocouple & Pt-100 Input. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates That Unit is Operating in Loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC. Operating Humidity Limit:- 10 to 90%, Non-condensing. Mounting:- Din Rail Mounting. Material of Encapsulation:- Epoxy.

.
New

Pressure Transmitter

Pressure transmitters translate low-level electrical outputs from pressure sensing devices to higher-level signals that are suitable for transmission and processing. They use many different sensing technologies and can measure the pressure of liquids and/or gases. Elastic elements when subjected to pressure get deformed. This deformation when measured gives an indication of the applied pressure. These elements may be in the form of Diaphragm, Bourdan Tube, Capsules, Bellows, and Helical Tube. Etc. These deformations can be measured by mechanical means. Features Head or Rail Mounting. Field mounting (Optional) Highly stable Analog design. Built in ‘cold junction compensation’ for thermocouple. Linearization & 3rd wire compensation for RTD. Wide supply voltage rang Compact & cost effective. Technical Specification Input : Pt-100 RTD, 2 OR 3wire. /Thermocouple Output : 2 wire 4 to 20mA corresponding to defined input temperature range. Operating Voltage : Nominally 24 VDC, can range from 12V to 36V. Maximum Load in Loop : 250 Ohm for 24VDC supply. Basic Accuracy:- +/- 0.5% of FSD. Ambient Operating Temperature Range:- 0 to50°C. Indication(s):- Red LED “ON” indicates that unit is operating in loop. Material of Encapsulation:- Epoxy.

.
New

Temperature Panel Mounting Transmitter

Specifications:- Input :- Pt-100RTD, 2 or 3 wire. / Thermocouple. Output :- 2 wire 4 to 20 mA corresponding to defined input temperature range. Operating Voltage :- Normally 24VDC,can range from 12V to 36V. Basic accuracy :- 0.5% of FSD Change of current o/p with Ambient Temperature :- <± 0.01% for span per ºC change Change of current o/p with supply voltage :- < ± 0.001% of span per volt, from 12V to 3V. Linearization Circuitry Error :- < 0.05% of span at any current. Ambient Operating Temperature Range :- 0ºC to 70ºC Indication :- Red LED “ON” indicates that units is operating in loop. Operating Humidity Limit :- 5 to 90%, Non-condensing. Material of Encapsulation :- Epoxy.

.
New

Humidity Transmitter

The Humidity sensor reacts very quickly on humidity leaps and measures accurately and free of any hysteresis. These characteristics suits especially good for a precise and quick control of the room climate. These are compact Transmitters for humidity, temperature and combined humidity / temperature with excellent price / performance ratio. Advantages: Calibration free Ready to use Precise humidity measurement Drift stable thanks to wide sensor area Available with optional temperature sensor Smallest dimensions Mechanical robust and easy to integrate Different output options on request Technical Data: Measurement Principle :- Capacitive humidity sensor Humidity measurement range :- 0 to 100%Rh Operating temperature :- -25 to +85°C Operating voltage :- 8 to 32VDC Current consumption : 4 to 20mA Output signal :- 4 to 20mA (0 to 100%Rh) Temperature sensor :- optional Pt100/Pt1000. Accuracy :- < 3% Rh Terminal connectors :- Soldering terminals for VCC, Analog out 4 to 20mA, Loop-through of optional temperature sensor.

.
New

Two Wire Loop Power Temperature Transmitter (Head Mounting)

Features: Head mounting/ Rail Mounting Highly stable Analog design. Built in ‘cold junction compensation’ for Thermocouple. Linearization & 3rd wire compensation for RTD. Wide supply voltage range Compact & cost effective. Technical Specifications Input :- Pt-100 RTD, 2 or 3 Wire. / Thermocouple Output :- 2 Wire 4 to 20mA Corresponding to Defined Input Temperature Range. Operating Voltage :- Nominally 24VDC, Can Range from 12V to 36V. Maximum Load in Loop:- Vin-8/20 Basic Accuracy:- +/- 0.25% for RTD , +/- 75% for Thermocouple. Linearization Circuitry Error:- <0.05% of Span at Any Current. Ambient Temperature Operating Range:- 0 to 50° C. Indication(S):- Red LED “ON” Indicates That Unit is Operating in Loop. Protection:- Reverse Polarity Protected to 500V Surge Suppression at 50VDC Operating Humidity Limit:- 10 to 90%, Non-condensing. Material of Encapsulation:- Epoxy.